Rhinomanometer and Tympanometer Combi

This PC-module combines advanced ENT diagnostics with modern design, integrating tympanography and rhinomanometry to save costs and space. In Tymp-Mode, it performs automatic impedance measurements in seconds, with results displayed on a PC monitor for verification. One-handed operation allows the clinician to steady the patient’s head while using the probe.In Rhino-Mode, quick adaptation with nose plugs enables use during routine exams. It calculates flow, pressure, and resistance in real time, providing immediate results. The device accommodates patients with beards, long hair, or mask anxiety, and includes a clinical face half-mask. Data and curves are displayed on the PC and can be stored or transmitted to practice software.

Technical Specifications

  • System: PC module
  • PC requirement: Pentium PC from 500 MHz, USB 2.0 port, Windows XP, 7, 8, 10 (32/64 bit)
  • Dimensions: 330 x 80 x 265 mm (WxHxD)
  • Power supply: 13.2 V, external power supply 100-240 V, 50/60 Hz, 30 W
  • Rhinomanometer accessories: 4 nasal olives small, 4 nasal olives medium, 4 nasal olives large, 2 flow measuring probes, 2 sets of measuring hoses, foot switch, probe holder, USB cable, Power supply, installation CD, user manual
  • Optional accessories: Face half mask
  • Tympanometer accessories: Set of earplugs, probe holder, headphones DD 45 C (with contra option), USB cable, power supply, installation CD, operating instructions

Tympanometer:

  • System: Impedance and reflex measurement
  • Measuring tone: 226 Hz, 85 dB SPL
  • Print range: +200 to -400 daPa
  • Pressure change: 300 daPa/sec
  • Measuring time: 2 sec. for compliance
  • Reflex tones: 500, 1000, 2000 and 4000 Hz at 85, 95 and 105 dB SPL
  • Reflex detection: automatically
  • Reflex measurement: ipsi-lateral and optionally contralateral
  • Pressure calibration: automatically when dialing
  • Status display: three-color LED in the probe, detailed display symbols
  • Page change: automatic or manual

Rhinomanometer:

  • Measurement method: anterior intrinsic current measurement (according to paragraph 1409)
  • Respiratory volume flow: 0-900 ml/s inspiration and expiration
  • Differential pressure: 0-50 daPa
  • Functional check: using 2 measuring bars in the display
  • Averaging calculation: over max. 5 measurement curves
  • Pressure calibration: automatically when dialing
  • Depiction: as nose pliers and numerically right + left
  • Automatic calculation of: Pressure in daPa, flow in ml/sec, total flow, percentage for right and left, resistance coefficient at 75, 150 and 300 daPa
  • Application: Detection of allergies after provocation, diagnostics of obstructed nasal breathing, functional control after nasal surgery, control after administration of medication